RoofUnder Construction3p · 2 filings · 11 docs
ArchitectureFire ProtectionMechanical
Issued Permit Scope
General Construction · Mechanical Systems · Sprinklers
General construction filed for interior renovations on floors 3, 9, and 11, as shown on plans filed herewith, and to obtain an amended Certificate of Occupancy.
On file for this project
5 documents · 2 drawing sheets
REPLACEMENT OF SPLIT SYSTEM ON FLOOR 014 AND THE ROOF WITH A TOTAL CAPACITY OF 4 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
On file for this project
6 documents · 1 drawing sheet
Bulkhead3p · 2 filings · 5 docs
EquipmentMechanicalStructural
Installation of suspended scaffold for facade work or inspection.
On file for this project
3 documents · 1 drawing sheet
IRA to assist with FISP
On file for this project
2 documents · 2 drawing sheets
Floor 17
Fire Protection
Issued Permit Scope
Sprinklers
Floor 16Under Construction1 filing · 20 docs
Fire ProtectionMechanical
Issued Permit Scope
Mechanical Systems · Sprinklers
Sprinkler work as shown on plans filed herewith.
On file for this project
21 documents
Floor 15Under Construction7p · 3 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Structural work including removal of existing terracotta masonry at exterior wall to create new louver wall openings at floors 2-4, 8-9 and 15(C)/16(M). No change in use, egress, or occupancy.
On file for this project
6 documents
Sprinkler work as shown on the plans.
On file for this project
19 documents · 6 drawing sheets
Sprinkler work as shown on plans filed herewith. No change to use, egress or occupancy.
On file for this project
22 documents · 1 drawing sheet
Floor 14Under Construction16p · 10 filings · 20 docs
ArchitectureCivilDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Sprinkler work as shown on plans filed herewith.
On file for this project
21 documents · 5 drawing sheets
REPLACEMENT OF SPLIT SYSTEM ON FLOOR 014 AND THE ROOF WITH A TOTAL CAPACITY OF 4 TONS. NO CHANGE TO EGRESS, USE, OR OCCUPANCY.
On file for this project
6 documents
Architectural feature support, slab infill as per plans. No change in use, egress or occupancy.
On file for this project
3 documents · 1 drawing sheet
Latest 3 of 10 filings on this floor.
Floor 13Under Construction5p · 7 filings · 20 docs
ArchitectureGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Structural
General construction filed for interior renovations on floors 3, 9, and 11, as shown on plans filed herewith, and to obtain an amended Certificate of Occupancy.
On file for this project
5 documents
Application filed for minor interior work and to reflect a passive recreation terrace on the 13th Floor (14th Marketing Floor).
On file for this project
7 documents · 2 drawing sheets
Plumbing work filed for installation of new drinking fountain on 13th Floor (Construction)/14th Floor (Marketing).
On file for this project
4 documents · 1 drawing sheet
Latest 3 of 7 filings on this floor.
Floor 1216p · 4 filings · 19 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
Modify plumbing fixtures and related piping. No change in use, egress or occupancy.
On file for this project
6 documents · 3 drawing sheets
Remove and install interior partitions, ceilings, doors and finishes. NO change in use, egress or occupancy.
On file for this project
3 documents · 7 drawing sheets
Modify mechanical ductwork and related piping. No change in use, egress or occupancy.
On file for this project
6 documents · 5 drawing sheets
Latest 3 of 4 filings on this floor.
Floor 11Under Construction10p · 2 filings · 20 docs
ArchitectureFire ProtectionGeneralMechanicalPlumbing
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers
General construction filed for interior renovations on floors 3, 9, and 11, as shown on plans filed herewith, and to obtain an amended Certificate of Occupancy.
On file for this project
5 documents · 1 drawing sheet
Sprinkler work as shown on the plans.
On file for this project
19 documents · 9 drawing sheets
Floor 10
Floor 9Under Construction15p · 8 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
General construction filed for interior renovations on floors 3, 9, and 11, as shown on plans filed herewith, and to obtain an amended Certificate of Occupancy.
On file for this project
5 documents · 1 drawing sheet
Structural work including removal of existing terracotta masonry at exterior wall to create new louver wall openings at floors 2-4, 8-9 and 15(C)/16(M). No change in use, egress, or occupancy.
On file for this project
6 documents
Sprinkler work as shown on plans filed herewith.
On file for this project
21 documents · 3 drawing sheets
Latest 3 of 8 filings on this floor.
Floor 8Under Construction30p · 6 filings · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructuralOther
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Structural work including removal of existing terracotta masonry at exterior wall to create new louver wall openings at floors 2-4, 8-9 and 15(C)/16(M). No change in use, egress, or occupancy.
On file for this project
6 documents
Sprinkler work as shown on the plans.
On file for this project
33 documents · 25 drawing sheets
Remove and install interior partitions, ceilings and doors as shown on plans filed herewith. No change in use, egress or occupancy.
On file for this project
5 documents · 1 drawing sheet
Latest 3 of 6 filings on this floor.
Floor 71 filing · 11 docs
Fire ProtectionMechanical
Issued Permit Scope
Mechanical Systems · Sprinklers
Modifications to existing Mechanical System as per plans filed herewith. No change in use, egress or occupancy.
On file for this project
11 documents
Floor 612p · 5 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Removal and installation of interior non bearing partitions and related finishes as per plans filed herewith. No change in use, egress or occupancy.
On file for this project
17 documents · 9 drawing sheets
Structural work as shown on plans filed herewith to include the removal of existing convenience stair, infill existing 5th floor stair slab opening, and framing for new masonry wall openings at the 5th and 6th floors.
On file for this project
9 documents
Sprinkler work as shown on plans filed herewith. No change to use, egress or occupancy.
On file for this project
22 documents · 1 drawing sheet
Latest 3 of 5 filings on this floor.
Floor 513p · 5 filings · 20 docs
ArchitectureDMFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Removal and installation of interior non bearing partitions and related finishes as per plans filed herewith. No change in use, egress or occupancy.
On file for this project
17 documents · 9 drawing sheets
Structural work as shown on plans filed herewith to include the removal of existing convenience stair, infill existing 5th floor stair slab opening, and framing for new masonry wall openings at the 5th and 6th floors.
On file for this project
9 documents · 1 drawing sheet
Sprinkler work as shown on plans filed herewith. No change to use, egress or occupancy.
On file for this project
22 documents · 1 drawing sheet
Latest 3 of 5 filings on this floor.
Floor 4Under Construction2 filings · 20 docs
Fire ProtectionMechanicalStructural
Issued Permit Scope
Mechanical Systems · Sprinklers · Structural
Structural work including removal of existing terracotta masonry at exterior wall to create new louver wall openings at floors 2-4, 8-9 and 15(C)/16(M). No change in use, egress, or occupancy.
On file for this project
6 documents
Sprinkler work as shown on plans filed herewith.
On file for this project
21 documents
Floor 3Under Construction5p · 3 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
General construction filed for interior renovations on floors 3, 9, and 11, as shown on plans filed herewith, and to obtain an amended Certificate of Occupancy.
On file for this project
5 documents · 1 drawing sheet
Structural work including removal of existing terracotta masonry at exterior wall to create new louver wall openings at floors 2-4, 8-9 and 15(C)/16(M). No change in use, egress, or occupancy.
On file for this project
6 documents
Sprinkler work as shown on plans filed herewith.
On file for this project
21 documents · 4 drawing sheets
Floor 2Under Construction14p · 7 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Standpipe · Structural
Sprinkler/Standpipe work as shown on plans filed herewith.
On file for this project
19 documents · 12 drawing sheets
Structural work including removal of existing terracotta masonry at exterior wall to create new louver wall openings at floors 2-4, 8-9 and 15(C)/16(M). No change in use, egress, or occupancy.
On file for this project
6 documents
Sprinkler work as shown on plans filed herewith.
On file for this project
21 documents
Latest 3 of 7 filings on this floor.
Floor 1Under Construction11p · 18 filings · 20 docs
ArchitectureFire ProtectionMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sign · Sprinklers · Structural
Structural work as shown on plans filed herewith.
On file for this project
27 documents · 3 drawing sheets
ERECT AN ILLUMINATED BUSINESS ACCESSORY WINDOW SIGN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
3 documents
ERECT AN ILLUMINATED BUSINESS ACCESSORY WINDOW SIGN. NO CHANGE IN USE, EGRESS, OR OCCUPANCY.
On file for this project
3 documents
Latest 3 of 18 filings on this floor.
MezzanineUnder Construction11p · 3 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Structural work as shown on plans filed herewith.
On file for this project
27 documents · 8 drawing sheets
Structural work as shown on plans filed herewith.
On file for this project
26 documents · 4 drawing sheets
Modifications to existing systems as shown on drawings filed herewith. No change in use, egress or occupancy.
On file for this project
10 documents
CellarUnder Construction16p · 4 filings · 20 docs
ArchitectureDMFire ProtectionGeneralMechanicalPlumbingStructural
Issued Permit Scope
General Construction · Mechanical Systems · Plumbing · Sprinklers · Structural
Structural work as shown on plans filed herewith.
On file for this project
27 documents · 8 drawing sheets
REMOVAL AND INSTALLATION OF SPRINKLER HEADS AS SHOWN ON DRAWINGS. NO CHANGE TO USE, EGRESS OR OCCUPANCY.
On file for this project
18 documents · 5 drawing sheets
Structural work as shown on plans filed herewith.
On file for this project
26 documents · 5 drawing sheets
Latest 3 of 4 filings on this floor.
Site & exteriorUnder Construction10 filings · 20 docs
ArchitectureEquipmentMechanicalPlumbingStructural
Issued Permit Scope
Mechanical Systems · Plumbing · Sign · Supported Scaffold
ILLUMINATED NON-ADVERTISING ACCESSORY SIGN - IN PROPERTY LINES - YOGA JOINT. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
On file for this project
3 documents · 1 drawing sheet
ILLUMINATED NON-ADVERTISING DOUBLE-FACE PROJECTING ACCESSORY SIGN - Y. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
On file for this project
4 documents · 1 drawing sheet
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2014 building codes chapter 33. No change in use, egress and/or occupancy with this application.
On file for this project
2 documents · 8 drawing sheets
Latest 3 of 10 filings on this floor.
Filed — no permit issued9 filings · 20 docs
ArchitectureFire ProtectionGeneralMechanicalStructural
No filed description on record for this project.
On file for this project
5 documents · 11 drawing sheets
Modify sprinkler heads and related piping as per plans. No change in use, egress or occupancy.
On file for this project
4 documents · 3 drawing sheets
Roof replacement as shown on plans filed herewith. No change in use, egress or occupancy.
On file for this project
5 documents · 7 drawing sheets
Latest 3 of 9 filings on this floor.