← Back
Office, 20+ stories, with or without commercial
693 5 AVENUE
MANHATTAN · BIN 1035742
💬 Discuss this project
1991Year Built
20Stories
O4Building Class
C5-3Zoning
101,319 sfGross Floor Area
4Units
LL97 Covered0 Open ViolationsFISP: SAFE
Office, 20+ stories, with or without commercial · Owner of record: 693 FIFTH OWNER LLC · 5,625 sf lot · 18.01 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentLandscape
Permit Issued — active, not yet Signed-off
RoofUnder Construction8p · 2 filings · 20 docs
Bulkhead1p · 1 filing · 2 docs
Floor 192p · 1 filing · 3 docs
Floor 18Under Construction6p · 1 filing · 11 docs
Floor 17Under Construction20p · 2 filings · 20 docs
Floor 16Under Construction31p · 2 filings · 20 docs
Floor 15Under Construction26p · 6 filings · 20 docs
Floor 14
Floor 13
Floor 12Under Construction46p · 6 filings · 20 docs
Floor 11Under Construction15p · 4 filings · 20 docs
Floor 1010p · 3 filings · 17 docs
Floor 98p · 6 filings · 20 docs
Floor 83p · 1 filing · 16 docs
Floor 7
Floor 66p · 2 filings · 20 docs
Floor 53p · 3 filings · 14 docs
Floor 43p · 3 filings · 14 docs
Floor 3
Floor 2
Floor 1
3 jobs · most recent 07/02/2026
Ventilation Systems Air Conditioning Systems Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
07/02/2026Signed-offPRODIGY CONSTRUCTION INCHeating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Titus Titus DTFS-F 41,400 BTU · Vav Box ×2
TITUS - DTFS-F 24,400 BTU ×1
Titus - DTFS-F 18,300 BTU ×1
Price Price FDC Series Fan Powered Terminal Unit FD-1-3-30 *does not have an efficiency rating in COP/EER/SEER 42,000 BTU · Exhaust Fan ×3
Price FDC Series Fan Powered Terminal Unit FDC-1-3-20 *does not have an efficiency rating in COP/EER/SEER 19,000 BTU · Exhaust Fan ×1
Ventilation
Panasonic PANASONIC - FV-0511VKS1 80 CFM · Exhaust Fan ×2
Greenheck Bathroom Exhaust Fan SP-AP0511W 80 CFM · Exhaust Fan ×2
06/19/2026Permit IssuedFOUR STAR AIR CON'D CO LLAir Conditioning Systems, Ventilation Systems
Cooling
Iec HDY06 15,751 BTU · Fan Coil Indoor ×2
HDY10 37,160 BTU · Fan Coil Indoor ×1
HDY20 63,916 BTU · Fan Coil Indoor ×1
Ventilation
Greenheck CSP-A390-VG 140 CFM · Exhaust Fan ×1
CSP-A700-VG 300 CFM · Exhaust Fan ×1
06/20/2025Signed-offPOWER COOLING INCAir Conditioning Systems
Cooling
Carrier 30MPW0665S-20117 70 tons · Chiller ×4
7 jobs · most recent 06/29/2026
Sprinkler System
FiledStatusContractorScope
06/29/2026Permit IssuedMPS PLUMBING & HEATING IN75 heads
06/19/2026Permit IssuedDOVAL PLBG & HTG CORPSprinkler System
11/26/2025———
11/26/2025——44 heads
11/26/2025Permit IssuedENCORE FIRE PROT SVS INC46 heads
11/26/2025———
03/24/2023Signed-offLT FIRE PROTECTION CORP—
8 jobs · most recent 06/29/2026
Water/Sanitary
FiledStatusContractorScope
06/29/2026Permit IssuedMPS PLUMBING & HEATING INCWater/Sanitary
06/19/2026Permit IssuedDOVAL PLBG & HTG CORPWater/Sanitary
11/26/2025——Water/Sanitary
11/26/2025——Water/Sanitary
11/26/2025——Water/Sanitary
11/26/2025——Water/Sanitary
11/22/2024——Water/Sanitary
03/24/2023——Water/Sanitary
15 jobs · most recent 09/13/2026
General Wiring
FiledStatusContractorScope
09/13/2026CompleteA&L ELECTRIC & AUTOMATIONGeneral Wiring
07/15/2026Permit IssuedCOBRA ELECTRICAL NYC LLCGeneral Wiring
05/06/2026Permit IssuedR & T ELECTRICAL CORPGeneral Wiring
03/07/2025CompleteA.S.K. ELECTRICAL CORPGeneral Wiring
09/09/2024CompleteELECSERV INC5 meters
08/23/2024Permit IssuedMEGA ELEC'L CONTR'G, INCGeneral Wiring
07/24/2024CompleteAL-LECTRIC ELECT'L CONTRGGeneral Wiring
10/03/2023CompleteCROSSWIRE ELECTRICAL INCGeneral Wiring
01/13/2023CompleteMETROPOLIS ELECTRIC CORPGeneral Wiring
10/24/2022CompleteCOMMERCIAL ELECT CONT INCGeneral Wiring
08/26/2022CompleteTOP SHELF ELECTRIC CORP—
08/15/2022CompletePATRIOT ELECTRIC CORPGeneral Wiring
12/18/2020CompleteFLAG ELECTRIC INC—
11/12/2020CompleteUPDATE SYSTEMS ELECTRICALGeneral Wiring
03/31/2020CompleteE-J ELEC. INSTALLATION COGeneral Wiring
1 job · most recent 06/04/2026
FiledStatusContractorScope
06/04/2026Permit IssuedSTRUCTUAL PRESV SYSTEM—
Building Lifecycle
All (281)Filed (71)Permit Issued (68)Signed Off (28)Facade (FISP) (9)Violation (60)Inspection (45)
09/15/2026
Permit issued — Supported Scaffold
M01458801-I1-SF
08/28/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
08/24/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
07/31/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/22/2026
Permit issued — Sprinklers
M01405932-S2-EW-SP
07/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
07/02/2026
Filed — Alteration
WORK TO INCLUDE NEW PLUMBING FIXTURES FOR NEW TOILET, EXAM ROOMS, INFUSION SUITES, PANTRY & TOILETS. RELOCATION OF SELECT SPRINKLER HEADS. WORK ON 17TH FLOOR INTERIORS ONLY.
M01349942-P1
07/02/2026
Inspection — Pass-Final PL - Underground
Pass
View inspection ↗
06/30/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/29/2026
Filed — Alteration
RENOVATE EXISTING 12TH FLOOR OFFICE SPACE TO NEW PROFESSIONAL (MEDICAL) OFFICE - NO AMENDED CO. NEW NON-LOAD BEARING PARTITIONS, NEW LIGHTING, NEW CEILINGS, NEW INTERIOR DOORS, NEW MILLWORK, FLOORING & FINISHES NO CHANGE OF EGRESS, USE OR OCCUPANCY
M01371858-P1
06/29/2026
Permit issued — Mechanical Systems
M01405932-S3-MS
06/26/2026
Permit issued — Plumbing
M01405932-S1-PL
06/26/2026
Permit issued — General Construction
M01405932-I1-GC
06/19/2026
Filed — Alteration
MODIFY EXISTING SPRINKLER SYSTEM FOR NEW OFFICE LAYOUT AND PER PLANS FILED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01405932-S2
06/18/2026
Filed — Alteration
MODIFY EXISTING SPRINKLER SYSTEM FOR NEW OFFICE LAYOUT AND PER PLANS FILED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01405932-S3
06/18/2026
Filed — Alteration
MODIFY EXISTING SPRINKLER SYSTEM FOR NEW OFFICE LAYOUT AND PER PLANS FILED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01405932-S1
06/18/2026
Inspection — Pass-Final SP - Up to 9 Requested Floors
Pass
View inspection ↗
06/05/2026
Inspection — Pass-Final SP - Up to 9 Requested Floors
Pass
View inspection ↗
06/04/2026
Filed — Alteration
FISP INSPECTION (Facade Inspection Safety Program) INDUSTRIAL ROPE ACCESS TECHNIQUES AND METHODS. SEE ATTACHED PLANS Designated Primary Site supervisor: Jesus Decola
M01199170-P1
06/02/2026
Permit issued — Suspended Scaffold
M01199170-I1-SC
05/21/2026
Filed — Alteration
MODIFY EXISTING SPRINKLER SYSTEM FOR NEW OFFICE LAYOUT AND PER PLANS FILED. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
M01405932-I1
05/18/2026
Permit issued — Sprinklers
M01371858-S3-EW-SP
05/13/2026
Permit issued — Mechanical Systems
M01371858-S2-MS
05/05/2026
Permit issued — General Construction
M01371858-I1-GC
05/04/2026
Filed — Alteration
RENOVATE EXISTING 12TH FLOOR OFFICE SPACE TO NEW PROFESSIONAL (MEDICAL) OFFICE - NO AMENDED CO. NEW NON-LOAD BEARING PARTITIONS, NEW LIGHTING, NEW CEILINGS, NEW INTERIOR DOORS, NEW MILLWORK, FLOORING & FINISHES NO CHANGE OF EGRESS, USE OR OCCUPANCY
M01371858-S2
05/04/2026
Filed — Alteration
RENOVATE EXISTING 12TH FLOOR OFFICE SPACE TO NEW PROFESSIONAL (MEDICAL) OFFICE - NO AMENDED CO. NEW NON-LOAD BEARING PARTITIONS, NEW LIGHTING, NEW CEILINGS, NEW INTERIOR DOORS, NEW MILLWORK, FLOORING & FINISHES NO CHANGE OF EGRESS, USE OR OCCUPANCY
M01371858-S3
04/28/2026
Permit issued — Plumbing
M01371858-S1-PL
04/24/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
04/17/2026
Filed — Alteration
RENOVATE EXISTING 12TH FLOOR OFFICE SPACE TO NEW PROFESSIONAL (MEDICAL) OFFICE - NO AMENDED CO. NEW NON-LOAD BEARING PARTITIONS, NEW LIGHTING, NEW CEILINGS, NEW INTERIOR DOORS, NEW MILLWORK, FLOORING & FINISHES NO CHANGE OF EGRESS, USE OR OCCUPANCY
M01371858-I1
04/17/2026
Filed — Alteration
RENOVATE EXISTING 12TH FLOOR OFFICE SPACE TO NEW PROFESSIONAL (MEDICAL) OFFICE - NO AMENDED CO. NEW NON-LOAD BEARING PARTITIONS, NEW LIGHTING, NEW CEILINGS, NEW INTERIOR DOORS, NEW MILLWORK, FLOORING & FINISHES NO CHANGE OF EGRESS, USE OR OCCUPANCY
M01371858-S1
03/05/2026
Permit issued — Sprinklers
M01349942-S3-EW-SP
03/02/2026
Permit issued — Plumbing
M01349942-S1-PL
02/26/2026
Permit issued — General Construction
M01349942-I1-MS
02/26/2026
Permit issued — Mechanical Systems
M01349942-I1-GC
02/17/2026
Filed — Alteration
WORK TO INCLUDE NEW PLUMBING FIXTURES FOR NEW TOILET, EXAM ROOMS, INFUSION SUITES, PANTRY & TOILETS. RELOCATION OF SELECT SPRINKLER HEADS. WORK ON 17TH FLOOR INTERIORS ONLY.
M01349942-S1
02/17/2026
Filed — Alteration
WORK TO INCLUDE NEW PLUMBING FIXTURES FOR NEW TOILET, EXAM ROOMS, INFUSION SUITES, PANTRY & TOILETS. RELOCATION OF SELECT SPRINKLER HEADS. WORK ON 17TH FLOOR INTERIORS ONLY.
M01349942-S3
02/17/2026
Filed — Alteration
WORK TO INCLUDE NEW PLUMBING FIXTURES FOR NEW TOILET, EXAM ROOMS, INFUSION SUITES, PANTRY & TOILETS. RELOCATION OF SELECT SPRINKLER HEADS. WORK ON 17TH FLOOR INTERIORS ONLY.
M01349942-I1
02/11/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
02/04/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
12/30/2025
Permit issued — Sprinklers
M01322455-S1-EW-SP
12/15/2025
Signed off — Alteration
MECHANICAL WORK ASSOCIATED WITH OFFICE RENOVATION AS PER PLANS FILED.,
M01041001-I1
12/12/2025
Signed off — Alteration
MECHANICAL WORK ASSOCIATED WITH OFFICE RENOVATION AS PER PLANS FILED.,
M01041001-S2
12/03/2025
Permit issued — Mechanical Systems
M01322397-S3-MS
12/03/2025
Permit issued — General Construction
M01322483-S2-GC
12/03/2025
Permit issued — Mechanical Systems
M01322455-S3-MS
12/03/2025
Permit issued — General Construction
M01322455-S2-GC
12/03/2025
Permit issued — General Construction
M01322397-S2-GC
12/03/2025
Permit issued — Mechanical Systems
M01322483-S3-MS
12/02/2025
Permit issued — Mechanical Systems
M01322427-S3-MS
12/02/2025
Permit issued — General Construction
M01322427-S2-GC
11/26/2025
Filed — Alteration
Filing for the removal of existing sprinkler heads and piping on the 17th floor and installation of temporary sprinkler loop as per plans filed herewith.
M01322455-S2
11/26/2025
Filed — Alteration
Filing for the removal of existing hvac units, exhaust fans, and associated ductwork on the 16th floor as per plans filed herewith.
M01322427-S1
11/26/2025
Filed — Alteration
Filing for the removal of existing sprinkler heads and piping on the 17th floor and installation of temporary sprinkler loop as per plans filed herewith.
M01322455-S1
11/26/2025
Filed — Alteration
Filing for the removal of entire plumbing system on the 12th floor as per plans filed herewith.
M01322397-S2
11/26/2025
Filed — Alteration
Filing for the removal of existing sprinkler heads and piping on the 18th floor and installation of temporary sprinkler loop as per plans filed herewith.
M01322483-S1
11/26/2025
Filed — Alteration
Filing for the removal of existing sprinkler heads and piping on the 18th floor and installation of temporary sprinkler loop as per plans filed herewith.
M01322483-S2
11/25/2025
Filed — Alteration
Filing for the removal of existing hvac units, exhaust fans, and associated ductwork on the 16th floor as per plans filed herewith.
M01322427-I1
11/25/2025
Filed — Alteration
Filing for the removal of existing sprinkler heads and piping on the 18th floor and installation of temporary sprinkler loop as per plans filed herewith.
M01322483-S3
11/25/2025
Filed — Alteration
Filing for the removal of entire plumbing system on the 12th floor as per plans filed herewith.
M01322397-I1
11/25/2025
Filed — Alteration
Filing for the removal of existing sprinkler heads and piping on the 17th floor and installation of temporary sprinkler loop as per plans filed herewith.
M01322455-I1
Latest 60 of 281 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
COLLIERS TRI-STATE3407/08/2026
693 FIFTH OWNERS LLC C O SAVITT PAR407/08/2026
693 FIFTH OWNERS1703/22/2026
MICHILLI503/22/2026
SCAFFOLDING LLC SPRING203/22/2026
TAKASHINAYU103/22/2026
TAKSHIMAYA CO.103/22/2026
TAKASHIMAYA 5TH AVE CORP603/22/2026
TAKASHIMAYA 5AVE CORP.103/22/2026
THE HARDMAN GROUP LLC103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/10/2016$455.0M—— → —$4,491/sf building
06/10/2016$68.2M—— → —$673/sf building
06/10/2016$1.8M—— → —$17/sf building
▾Filing Representatives (Expediters)
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ECOSTRUCTION GROUP INCGeneral Contractor807/08/2026
LT FIRE PROTECTION CORPFire Protection607/08/2026
W5 GROUP LLCGeneral Contractor407/08/2026
STRUCTURAL PRESERV SYSTEMGeneral Contractor403/21/2026
ABCAT ASSOCIATES INCGeneral Contractor407/08/2026
NUCOR CONSTRUCTION CORPGeneral Contractor403/21/2026
JAMES E FITZGERALD INCGeneral Contractor407/08/2026
A&A PLUMBING CORPPlumbing307/08/2026
MILL BROOK FIRE PROTECTIONFire Protection207/08/2026
RICKETTS, JOSEPHElectrical203/21/2026
AMERICON CONSTRUCTION INC.General Contractor207/08/2026
WILLIAM C. GERAKARIS P&HPlumbing207/08/2026
SENTINEL BUILDERS, LLCGeneral Contractor207/08/2026
ROBERT MARCHISOTTOElectrical203/21/2026
BOILERMATIC WELDING INDUSGeneral Contractor107/08/2026
FOUR STAR AIR CON'D CO LLGeneral Contractor107/01/2026
GREAT INTERIOR RENOVATIONSGeneral Contractor106/28/2026
HICK HOLDINGS, INCGeneral Contractor107/08/2026
HNL CONSTRUCTION COMPANYGeneral Contractor107/08/2026
MC SUPERSTRUCTURE INCGeneral Contractor109/16/2026
POWER COOLING INCGeneral Contractor104/09/2026
PRODIGY CONSTRUCTION INCGeneral Contractor104/09/2026
SIGNA DEVELOPMENT CORPGeneral Contractor106/27/2026
SPRING SCAFFOLDING LLCGeneral Contractor107/08/2026
SUPERIOR HVAC INCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
OUTSOURCE SPECIAL INSPECT2827307/02/2026
JUDGE ARCHITECTURE PC748406/29/2026
OBAID MIAN849306/19/2026
SAM MATHER ARCHITECT773105/21/2026
JMV CONSULTING ENGINEERIN804105/21/2026
AZA ENGINEERING LLC7235205/04/2026
KEYOWNER ENGINEERING, P.C4817102/17/2026
RLM ENGINEERING PLLC69131911/26/2025
VINCENT J. LIOTTA P. E.1974106/20/2025
JACK GREEN ASSOCIATES422111/22/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldPermit IssuedMC SUPERSTRUCTURE INC09/15/2026
DOB NOWSprinklersPermit IssuedDOVAL PLBG & HTG CORP07/22/2026
DOB NOWMechanical SystemsPermit IssuedFOUR STAR AIR CON'D CO LL06/29/2026
DOB NOWPlumbingPermit IssuedDOVAL PLBG & HTG CORP06/26/2026
DOB NOWGeneral ConstructionPermit IssuedGREAT INTERIOR RENOVATIONS06/26/2026
DOB NOWSuspended ScaffoldPermit IssuedSTRUCTUAL PRESV SYSTEM06/02/2026
DOB NOWSprinklersPermit IssuedMPS PLUMBING & HEATING INC05/18/2026
DOB NOWMechanical SystemsPermit IssuedHNL CONSTRUCTION COMPANY05/13/2026
DOB NOWGeneral ConstructionPermit IssuedSIGNA DEVELOPMENT CORP05/05/2026
DOB NOWPlumbingPermit IssuedMPS PLUMBING & HEATING INC04/28/2026
DOB NOWSprinklersPermit IssuedALLTYPE FIRE PROTECT LLC03/05/2026
DOB NOWPlumbingSigned-offZATOS PLBG AND HTG INC03/02/2026
DOB NOWGeneral ConstructionSigned-offSUPERIOR HVAC INC02/26/2026
DOB NOWMechanical SystemsSigned-offPRODIGY CONSTRUCTION INC02/26/2026
DOB NOWSprinklersPermit IssuedENCORE FIRE PROT SVS INC12/30/2025
DOB NOWMechanical SystemsPermit IssuedECOSTRUCTION GROUP INC12/03/2025
DOB NOWGeneral ConstructionPermit IssuedECOSTRUCTION GROUP INC12/03/2025
DOB NOWMechanical SystemsPermit IssuedECOSTRUCTION GROUP INC12/03/2025
DOB NOWGeneral ConstructionPermit IssuedECOSTRUCTION GROUP INC12/03/2025
DOB NOWGeneral ConstructionPermit IssuedECOSTRUCTION GROUP INC12/03/2025
DOB NOWMechanical SystemsPermit IssuedECOSTRUCTION GROUP INC12/03/2025
DOB NOWMechanical SystemsSigned-offECOSTRUCTION GROUP INC12/02/2025
DOB NOWGeneral ConstructionSigned-offECOSTRUCTION GROUP INC12/02/2025
DOB NOWSprinklersSigned-offRALPH W. LANDOLFI JR.06/24/2025
DOB NOWMechanical SystemsSigned-offPOWER COOLING INC06/23/2025
DOB NOWSuspended ScaffoldPermit IssuedSTRUCTUAL PRESV SYSTEM03/26/2025
DOB NOWMechanical SystemsSigned-offSENTINEL BUILDERS, LLC11/22/2024
DOB NOWPlumbingSigned-offLEGUCI PIPING&HEATING LLC11/08/2024
DOB NOWPlumbingSigned-offPROSTAR PLUMBING AND HEAT11/07/2024
DOB NOWMechanical SystemsSigned-offABCAT ASSOCIATES INC10/03/2024
DOB NOWGeneral ConstructionSigned-offABCAT ASSOCIATES INC10/03/2024
DOB NOWPlumbingSigned-offLT FIRE PROTECTION CORP09/26/2024
DOB NOWSprinklersSigned-offG. C. PLBG & HTG INC09/25/2024
DOB NOWGeneral ConstructionSigned-offSENTINEL BUILDERS, LLC09/13/2024
DOB NOWGeneral ConstructionSigned-offTOROVOLI CONSTRUCTION INC09/11/2024
DOB NOWMechanical SystemsSigned-offABCAT ASSOCIATES INC07/30/2024
DOB NOWSprinklersSigned-offVAND MECHANICAL INC07/24/2024
DOB NOWPlumbingSigned-offLT FIRE PROTECTION CORP07/17/2024
DOB NOWGeneral ConstructionSigned-offABCAT ASSOCIATES INC05/24/2024
DOB NOWPlumbingSigned-offA&A PLUMBING CORP06/26/2023
+ 60 more permits on file
▾Field Inspections (DOB CAP) — 45
DateTypeResultReport
08/28/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/24/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
07/31/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/06/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
07/02/2026Pass-Final PL - UndergroundPassView ↗
06/30/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/18/2026Pass-Final SP - Up to 9 Requested FloorsPassView ↗
06/05/2026Pass-Final SP - Up to 9 Requested FloorsPassView ↗
04/24/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
02/11/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
02/04/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/25/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
08/18/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/18/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/05/2025Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/05/2025Certified Sprinkler - SP - RoughingCertifiedView ↗
01/16/2025Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
01/16/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/14/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
01/14/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/15/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/01/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/26/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
09/26/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/25/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
Latest 25 of 45.
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
07/07/2026HVAC-R and service water heating equipmentJONAR MADRIAGAenergy_progress
07/07/2026FinalJONAR MADRIAGAprogress
07/07/2026Post-installed AnchorsJONAR MADRIAGAspecial
07/07/2026Energy Code Compliance InspectionsJONAR MADRIAGAprogress
07/07/2026Mechanical SystemsJONAR MADRIAGAspecial
07/07/2026Fire-Resistant Penetrations and JointsJONAR MADRIAGAspecial
07/07/2026Interior lighting powerJONAR MADRIAGAenergy_progress
07/07/2026HVAC-R and service water heating system controlsJONAR MADRIAGAenergy_progress
07/07/2026Lighting controlsJONAR MADRIAGAenergy_progress
07/07/2026HVAC-R and service water piping design and insulationJONAR MADRIAGAenergy_progress
07/07/2026Maintenance informationJONAR MADRIAGAenergy_progress
07/07/2026MeteringJONAR MADRIAGAenergy_progress
06/10/2026Interior lighting powerJONAR MADRIAGAenergy_progress
06/10/2026Lighting controlsJONAR MADRIAGAenergy_progress
06/10/2026HVAC-R and service water heating system controlsJONAR MADRIAGAenergy_progress
06/10/2026HVAC-R and service water piping design and insulationJONAR MADRIAGAenergy_progress
06/10/2026HVAC-R and service water heating equipmentJONAR MADRIAGAenergy_progress
06/10/2026Maintenance informationJONAR MADRIAGAenergy_progress
06/10/2026FinalJONAR MADRIAGAprogress
06/10/2026Energy Code Compliance InspectionsJONAR MADRIAGAprogress
06/10/2026Post-installed AnchorsJONAR MADRIAGAspecial
06/10/2026Mechanical SystemsJONAR MADRIAGAspecial
06/10/2026Fire-Resistant Penetrations and JointsJONAR MADRIAGAspecial
06/10/2026MeteringJONAR MADRIAGAenergy_progress
06/01/2026Energy Code Compliance InspectionsObaid Mianprogress
Latest 25 of 150.
▾Documents — 1,990 on file (BIS + DOB NOW)
▸Plans & Drawings67
▸DOB NOWPlans/Sketch60
09/02/2026M00761305-I1Request digital key ↗
09/02/2026M00587460-I1Request digital key ↗
09/01/2026M00777488-I1Request digital key ↗
Showing 3 of 60 on file for this type
▸DOB NOWPlans/Sketch - Plumbing3
09/05/2026M00212787-I1Request digital key ↗
09/05/2026M00246821-S1Request digital key ↗
Showing 2 of 3 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems2
09/05/2026M00212719-I1Request digital key ↗
09/05/2026M00246821-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
09/05/2026M00247003-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Structural1
09/05/2026M00212798-I1Request digital key ↗
▸Applications & Permits374
▸BISPLAN / WORK APPROVAL APPLICATION235
09/20/2023100075133Open ↗
09/11/2023100075133Open ↗
09/08/2023100075133Open ↗
Showing 3 of 235 on file for this type
▸BISWORK PERMIT APPLICATION138
10/08/2020140945636Open ↗
06/13/2020123875404Open ↗
06/13/2020123875404Open ↗
Showing 3 of 138 on file for this type
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Seals & Professional Certifications639
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION259
03/30/2020123770883Open ↗
03/30/2020123770883Open ↗
03/26/2020123875404Open ↗
Showing 3 of 259 on file for this type
▸DOB NOWProgress Inspector Seal & Signature94
09/23/2026M01322483-S3Open ↗
09/23/2026M00783903-I1Open ↗
09/02/2026M01322455-S3Open ↗
Showing 3 of 94 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT67
10/05/2020140945636Open ↗
03/26/2020123875404Open ↗
03/26/2020123875404Open ↗
Showing 3 of 67 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature65
09/05/2026M00212719-I1Open ↗
09/05/2026M00246821-S1Open ↗
09/01/2026M07997243-I1Open ↗
Showing 3 of 65 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST63
03/26/2020123875404Open ↗
09/05/2019123770883Open ↗
07/02/2019123755221Open ↗
Showing 3 of 63 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature51
09/23/2026M01322483-S3Open ↗
09/23/2026M00783903-I1Open ↗
09/23/2026M01322455-S1Open ↗
Showing 3 of 51 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM23
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 23 on file for this type
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION8
10/05/2020140945636Open ↗
Showing 1 of 8 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY8
10/05/2020140945636Open ↗
Showing 1 of 8 on file for this type
▸BISPC FULL REPORT1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Trade Schedules & Equipment161
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE46
07/02/2019123755221Open ↗
04/05/2019123730891Open ↗
Showing 2 of 46 on file for this type
▸BISSELF-CERT PLUMBING NOTICE41
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 41 on file for this type
▸BISEQUIPMENT USE PERMITS20
12/17/2018140720548Open ↗
Showing 1 of 20 on file for this type
▸BISSCHEDULE B - PLUMBING18
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 18 on file for this type
▸BISFA - FDNY APPROVAL : FD-FAA14
03/23/2023122542098Open ↗
02/10/2023123130209Open ↗
12/07/2022122195043Open ↗
Showing 3 of 14 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT11
12/17/2018140720548Open ↗
Showing 1 of 11 on file for this type
▸BISSPRINKLER INSP REPORT : FP-858
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISFIRE PROTECTION PLAN(FPP): FDNY APPROVAL1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BIS* FIRE PROTECTION PLAN (FPP): FDNY APPROVAL1
09/26/2023100075133Open ↗
▸BISSTANDPIPE (SD) SIGNOFF1
09/26/2023100075133Open ↗
▸Safety & Tenant Protection2
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Environmental & Asbestos69
▸DOB NOWDEP ACP-5: Asbestos Assessment Report31
09/01/2026M08026937-I1Open ↗
09/01/2026M08021985-I1Open ↗
09/01/2026M08047383-I1Open ↗
Showing 3 of 31 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER20
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 20 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'8
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 8 on file for this type
▸BISASBESTOS-EXEMPTION (ASB4)2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Energy Compliance125
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS66
03/26/2020123875404Open ↗
09/05/2019123770883Open ↗
04/05/2019123730891Open ↗
Showing 3 of 66 on file for this type
▸BISAS-BUILT ENERGY ANALYSIS36
12/09/2020140945636Open ↗
12/02/2020123875404Open ↗
03/30/2020123770883Open ↗
Showing 3 of 36 on file for this type
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY6
12/02/2020123875404Open ↗
10/05/2020140945636Open ↗
06/13/2020123875404Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS5
10/05/2020140945636Open ↗
Showing 1 of 5 on file for this type
▸BISTECHNICAL REPORT: ENERGY4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISNYCECC ANALYSIS2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTR8: Energy Code Progress Inspections2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸DOB NOWEN2: As Built Energy Analysis2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISELECTRICAL APPLICATION FOR SIDEWALK SHED LIGHTING1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISLIGHTING IN DWELLING UNITS1
06/13/2020123875404Open ↗
▸Inspections & Test Reports19
▸BISTECHNICAL REPORT: RESPONSIBILITY14
12/09/2020140945636Open ↗
12/09/2020140945636Open ↗
12/02/2020123875404Open ↗
Showing 3 of 14 on file for this type
▸BISHYDRAULIC FLOW CALCULATIONS2
07/02/2019123755221Open ↗
Showing 1 of 2 on file for this type
▸BISTECHNICAL REPORT: CONCRETE/TEST CYLINDER2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISTECHNICAL REPORT: CONCRETE DESIGN MIX1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Approvals, Objections & Sign-offs132
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST80
03/27/2023122542098Open ↗
03/16/2023122209065Open ↗
03/16/2023122209065Open ↗
Showing 3 of 80 on file for this type
▸BISADMINISTRATIVE OBJECTIONS27
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 27 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE13
09/08/2023100075133Open ↗
07/26/2023100075133Open ↗
10/28/2020100075133Open ↗
Showing 3 of 13 on file for this type
▸BISLETTERS - SUPPORTING DOCUMENTATION5
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 5 on file for this type
▸BISSUPERSEDING LETTER4
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 4 on file for this type
▸BISCONSTRUCTION CODE DETERMINATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISMaster Plumber Seal Temporary Approval Letter1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸Cost, Insurance & Ownership177
▸BISCOST AFFIDAVIT171
03/27/2023122542098Open ↗
03/06/2023122551345Open ↗
03/06/2023122195043Open ↗
Showing 3 of 171 on file for this type
▸BISCOST AFFIDAVIT (FINAL): PW34
03/27/2023122542098Open ↗
03/16/2023122209065Open ↗
03/07/2023122551345Open ↗
Showing 3 of 4 on file for this type
▸BISPROJECT-SPECIFIC GL INSURANCE2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸Filing & Intake Forms213
▸BISEFILING COVER SHEET123
03/26/2020123875404Open ↗
03/26/2020123875404Open ↗
09/05/2019123770883Open ↗
Showing 3 of 123 on file for this type
▸BISADDITIONAL INFORMATION52
09/26/2023100075133Open ↗
10/28/2020100075133Open ↗
Showing 2 of 52 on file for this type
▸BISBOROUGH INTAKE FORM28
10/21/2020100075133Open ↗
03/30/2020123770883Open ↗
09/20/2019123399722Open ↗
Showing 3 of 28 on file for this type
▸BISEFILING JOB APPLICATION COVER SHEET10
10/05/2020140945636Open ↗
Showing 1 of 10 on file for this type
▸Other Documents8
▸DOB NOWIRA Certification3
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 3 on file for this type
▸BISEXTERNAL FORMS - SUPPORTING DOCUMENTATION2
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 2 on file for this type
▸BISOTCR MONITOR CERTFICATION1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISENVIRONMENTAL "E" DEP NOTICE TO PROCEED1
On file, but not among the 200 most recently loaded documents for this source.
Showing 0 of 1 on file for this type
▸BISPRIOR TO FINAL CO PROVIDE EVIDENCE OFBUILDER PAVEMENT PLAN OR EXEMPTION1
09/26/2023100075133Open ↗